Portable Large Caliber Double Clamp Digital Phase Voltammeter Ammeter0.00V -600V
Portable Large Caliber Double Clamp Digital Phase Voltammeter Ammeter0.00V -600V Product Details Model ETCR4000A Intelligent Double Clamp Digital Phase Voltmeter ETCR4020 Large Caliber Double Clamp Digital Phase Voltammeter CT Size Φ8mm 35mm x 40mm Voltage Range AC 0.00V ~ 600V Error:±(0.5% range) AC 0.00V ~ 600V Error:±(0.5% range) Current Range AC 0.0mA ~ 20.0A Error:±(0.5% range) AC 0mA ~ 600A Error:±(0.5% range) Phase Range 0.0°~360.0° Error:±1° 0.0°~360.0° Error:±1° Frequency Range 45.00Hz ~ 65.00Hz Error:±(1.0 % range) 45.00Hz ~ 65.00Hz Error:±(1.0 % range) Active power Range 0.0W ~ 12kW Error:±(1.0 % range) 0.0W ~ 360kW Error:±(1.0 % range) Reactive power Range 0.0var ~ 12kvar Error:±(1.0 % range) 0.0var ~ 360kvar Error:±(1.0 % range) Apparent power Range 0.0VA ~ 12kVA Error:±(1.0 % range) 0.0VA ~ 360kVA Error:±(1.0 % range) Power factor Range 1-1.000 ~ 1.000 Error:± B110.03 11-1.000 ~ 1.000 Error:± 0.03 Meter Weight 1140g 1170g Power Supply DDC9V Alkaline battery LR61.5V AAX6PCS Detection Rate About 2 second/times Meter Dimension 196mmx92mmx54mm Display Mode 2.8-inch TFT color LCD screen, display field: 58mm × 44mm Data Storage 1200 groups Data Hold In testing, press HOLD key to hold the data, “HD”symbol display Communication Interface USB interface, storage data upload to computer, convenient to analyze management data Auto Shut Down 15 minutes after boot up, the meter shuts down automatically without any operation Voltage Detection When the battery voltage is lower than 7.2V, low battery symbol display, remind to replace battery Cable Length Test wire length 1.5m; current clamp wire length 2m x o5mm Input Impedance Test voltage input impedance: 1MΩ Working Current Max power consumption of open backlight: 135mA; Meter power consumption of close backlight: 90mA (optional accessorie Host: 1PCS; Current Clamp:2PCS; Test wire: 4PCS; USB data cable: 1PCS; Meter case: 1PCS Product FunctionIn the case of the tested circuit is not open-loop, measure two AC voltages, current, phase between voltages, phase between currents, phase, frequency, phase sequence, active power, reactive power, apparent power, and power factor between voltage and current. Discriminate the transformer wiring group, inductive and capacitive circuits, test the secondary circuit and the busbar protection system, read the phase relationship between the CTs of the differential protection groups, check the wiring of the meter for correctness, and repair the line equipment, etc.Product Feature 1.Intelligent design, re3duce the complexity of operation, reduce the possibility of misoperation, with high precision, high stability, low power consumption, easy to use and other advantages. 2.Adopt voltage transformer and current clamp to input, no high voltage inside the meter, complete isolation between 2 input channels, safe and reliable. 3.Small sharp clamp is suitable for flat cable dense site 4.The test wire adopts special electric power cable, all the plug of spring rod and crocodile clip have insulated protection. The instrument is insulated with non slip sheath. 5.With USB interface, Data storage: 1200 groups. Through the system software to upload the storage data to computer, convenient to read, save, report, print historical data, etc.
Double Clamp Digital Phase Voltmeter with Large Caliber Current Clamp 35mm×40mm
Clamp Jaw Size 35mm×40mm. Phase 0.0°~360° 0.1° ±1°. Phase:0.0°~360.0°. The test line adopts a special power cable, and the elastic rod plug and alligator clip are insulated and protected. Large-caliber current pliers are used, which are suitable for testing of thick wires and high currents.
Large Caliber Double Clamp Digital Phase Voltmeter AC Current Voltage Tester
Simultaneous phase test between UI, II and UU range : 0.0° ~360.0 °. Phase : 0.0 °~ 360.0 °. Round type current clamp: 35mm × 40mm. Phase : 0.1 °. Current : AC 0.0mA ~ 600A. Current : AC 0.1mA. Input Impedance.
Large Caliber Clamper Three-phase Digital Phase Voltmeter Voltage Current Tester
Large Caliber Clamper Three-phase Digital Phase Voltmeter Voltage Current Tester Note: Battery cannot be included during the shipping !!! Introduction: Large Caliber Three-phase Digital Phase Voltmeter is a multifunctional, digital and intelligent instrument specially developed by our company for field testing. It has the characteristics of high accuracy, high stability, low power consumption and convenient to use etc. Under the condition of the tested circuit does not open-loop, it can measurement of three-phase AC voltage, current, phase between voltages, phase between current, phase between current and voltage, frequency, phase sequence, active power, reactive power, apparent power, power factor, current vector sum, judge transformer wiring group, sensibility and capacitive circuit, test the secondary circuit and differential bus protection system, read the phase relationship between differential protection between each groups CT, check watt hour meter wiring correctly or not, maintenance line equipment, etc., To provide a safe, accurate and convenient new power meter for electricity inspectors.Large Caliber Three-phase Digital Phase Voltmeter with shake proof, skid proof, and high insulation sheath. Adopts 240dotsX160dots LCD screen, dynamic display, vector diagram indication, clear and obvious, which shows the exquisite and luxurious appearance. The instrument adopt large caliber current clamp, suitable for testing of thick conductor and large current place.Large Caliber Three-phase Digital Phase Voltmeter also name intelligent three phase digital phase voltmeter, multifunction three phase digital phase voltmeter and three clamp digital phase voltmeter etc. Suitable for electric power, petrochemical, metallurgy, railway, industrial and mining enterprises, scientific research institutions, measurement departments. It is especially suitable for electric energy billing system and relay protection system. Function:Simultaneous measurement of three AC current, range: 0.0mA~600ASimultaneous measurement of three AC voltage, range: 0.00V~600VSimultaneous measurement of UU, II, UI phase, range: 0.0°~360.0°Measurement frequency, phase sequence, active power, reactive power, apparent power, power factor and other parameters.Judgement of transformer wiring group, inductive, capacitive circuit and maintenance line equipment, etc. Specifications: Power SupplyDC9V alkaline batteries(1.5V LR6×6) (not included)Clamp35mm x 40mmLCD240dotsX160dotsRangeVoltage:AC 0.00V~600VCurrent:AC 0mA~600APhase:0.0°~360.0°Frequency:45.00Hz~65.00HzActive power:0.0W~240kWReactive power:0.0VAR~240kVARApparent Power:0.0VA~240kVAPower factor :-1~+1Current vector:0A~18000AResolutionVoltage:AC 0.01VCurrent:AC 1 mAPhase:0.1°Frequency:0.01HzActive power:0.1WReactive power:0.1VARApparent Power:0.1VAPower factor:0.001Current vector: 0.1AAccuracy±0.5% rangeDate Storage500 setsData upload functionUSB interface, the stored data upload computer, easy to analyze management dataAuto Power-off15 minutes off automaticallyPower ConsumptionWith backlight: MAX working Current about 80mA, the battery can work continuously for 8 hourswithout backlight: working current about 50mA,the battery can work continuously for 12 hoursWorking environment-10℃~40℃; below 80%RhStore environment-10℃~60℃; below 70%RhPhase sequencePositive: U1, U2, U3 or I1, I2, I3 The cursor flashes from left to rightInverting: U1, U2, U3 or I1, I2, I3 The cursor flashes from right to leftThe phase range of the measured signal when measuring phaseMeasuring U1-U2 phase: 30V ~ 500VMeasuring U1-I2 orI1-U2 Phase:10V~500V,10mA~10.00ATest line length1.5mCurrent clamp length2mmeasure time2s/timeData HoldPress the HOLD button during the test to hold the data, the “DH” symbol is displayedinput resistanceTest voltage input impedance is:1MΩLow batteryWhen battery voltage decreases to about 7.2V, battery voltage low icon will display, reminding to replace battery. (not included)Withstanding VoltageBetween the instrument line and the shell to withstand 1000V / 50Hz sine wave AC voltage for 1 minuteInsulationBetween the meter line and the jacket shell ≥ 100MΩStructureDouble insulated, with insulated vibration-proof jacketProtection TypeIEC61010-1 CAT Ⅲ 600V, IEC61010-031, IEC61326, Pollution 2Weight1360gDimension196mm×92mm×54mm Packing: PackageOuter PackageCartonInner PackageAluminum caseAccessoryMeter1 PCSCurrent Clamp3 PCSTest Wire4 PCSCommunication Cable1 PCSSoftware CD1 COPYAluminum case1 PCSManual1 PCSCertificate1 PCSWarranty Card1 PCS
Large Caliber Double Clamp Digital Phase Voltmeter with Clamp Jaw Size Φ40mm
Clamp Jaw Size 35mm×40mm. Phase 0.0°~360° 0.1° ±1°. Phase:0.0°~360.0°. The test line adopts a special power cable, and the elastic rod plug and alligator clip are insulated and protected. Backlight Function Yes, suitable for dim places and night use; turn off the backlight after five minutes of no operation.
High Accuracy Clamp Leakage Current Meter Digital Tester with AC 0.0mA to 600A
300A~600A: ±4%±5dgt. Overflow display. Accuracy(23℃±3℃. 35mm×21.5mm;display area:32mm×15mm. Communication Cable. Working Current. 99units, display FULL symbol indicate storage full. Relate Model:.
Clamp Leakage Current Meter AC Clamp Leakage Current Meter Measurement 0mA~600A
0mA ~ 600A. 300A ~ 600A: ±4%±5dgt. Sampling Rate. Overflow display. 35mm×21.5mm ; display area : 32mm×15mm. Communication Cable. Working Current. AC2KV/rms (between the core and outside shell).
Large Caliber Double Clamp Digital Phase Voltmeter with 0mA~600A Resolution 1mA
Current AC 0mA~600A 1mA ±(0.5%range). Current:AC 0mA~600A. Clamp Jaw Size 35mm×40mm. Phase 0.0°~360° 0.1° ±1°. Phase:0.0°~360.0°. The test line adopts a special power cable, and the elastic rod plug and alligator clip are insulated and protected.
Large Caliber Double Clamp Digital Phase Voltmeter with Current AC0mA~600A Φ40mm
Current AC 0mA~600A 1mA ±(0.5%range). Current:AC 0mA~600A. Clamp Jaw Size 35mm×40mm. Phase 0.0°~360° 0.1° ±1°. Phase:0.0°~360.0°. The test line adopts a special power cable, and the elastic rod plug and alligator clip are insulated and protected.