Hör GmbH & Co. Microwave Leakage Tester 24V AC/DC MLT 443
Digital AC DC Clamp Leakage Current Meter Range 0mA~60.0A AC/DC CT Size φ7mm
0mA~60.0A AC/DC. The tested wire in the center of the clamp jaw. Overflow display. Display Mode. Relate Model:. 35mm×21.5mm;display area:32mm×15mm. AC 45Hz ~ 400Hz. below 70%RH).
Leakage Current Clamp Meter 0-60A Portable
Clamp Leakage Current Meter AC Leakage Current Measurement Meter 0.01mA-300.0A
Clamp Leakage Current Meter AC Leakage Current Measurement Meter 0.01mA-300.0ANote: Battery not Included During The Shipping !!!Instruction:High Accuracy Clamp Leakage Current Meter suitable for measuring AC current and leakage current below 600V, range: 0.00mA~300.0A, CT size: 35mm x 40mm, the iron core adopts magnetic shielding technology, almost unaffected by the external magnetic field, strong anti-interference ability. Especially suitable for high accuracy small current measurement, adopt non-contact current measurement, safe and simple operation.The instrument is small size, high accuracy, performance stable and function perfect, which is one of the necessary tools for electrician safety inspection and maintenance..The instrument with data hold, data storage and other functions, can store 99 groups of data, the instrument connect computer by RS232 interface, stotage data can be uploaded to the computer, easy to read, analysis, save, print and so on. Characteristics:Measurement of AC current , leakage current, Range:AC 0.00mA~300.0AData Storage: 99 groupsPeak HoldLine Voltage: below 600VCT Size: 35mm x 40mm Specification:Model—-Range0.00mA~300.0AResolution10uACT Size35mm×40mmMeter Size184×70×37mmMeter Weight250gFunctionMeasurement of AC leakage current, AC current and on-line AC current.Power SupplyAlkaline dry battery 6LR61 9V,continues working 80 hoursTest ModeClamp CT, integration methodDisplay Mode4digits LCD displayLCD Dimension35mm×21.5mm;display area:32mm×15mmSampling Rateabout 2 times/sFrequencyAutomatic identification 50Hz/60HzShiftAutomaticallyAccuracy (23℃±3℃, below 70%RH)0~59A: ±1.5%±5dgt60A~199A: ±2%±5dgt200A~300A: ±4%±5dgtLine VoltageLine measurement below DC 600VCommunication InterfaceWith USB interface, storage data can be uploaded to computer, software monitoringData Storage99units, display FULL symbol indicate storage fullPeak HoldPeak capture and hold function, long press HOLD key and not release can display peak value in measurement.Data HoldData hold function: DH symbol displayOverflow displayExceed measure range overflow function: OL symbol displayAuto Shut Down5 Minutes after power on, the meter shuts down automatically without any operation to reduce battery consumptionBattery VoltageWhile battery voltage decreases to around 7.2V, will display low battery voltage symbol“ ”, and remind to replace the batteryWorking Current5mAWorking Temperature0℃ ~ 40℃,below 80%rhStorage Temperature-10℃ ~60℃,below 80%rhInsulating StrengthAC2KV/rms (between the core and outside shell)Suitable Safety StandardIEC1010-1、IEC1010-2-032、pollution, etc 2、CAT Ⅲ(600V)
Digital Clamp Leakage Current Meter with AC Range 0.001mA~60.00A Resolution 1uA
Overflow display. Specification:. 175×70×38mm. Relate Model:. 35mm×21.5mm;display area:32mm×15mm. Automatic identification 50Hz/60Hz. (23℃±3℃,below 70%RH). Alkaline dry battery 6LR61 9V,continues working 80 hours(.
Leakage Current Meter Three Channels with Range 0.00mA ~20A Jaw Size 25×30mm
0.00mA ~20A. Three Channel Clamp Leakage Current Monitoring Recorder. The current clamp adopts magnetic shield and digital integration technology, which has strong anti-interference and high precision.
Automotive Fuse Current Tester LCD Display Car Leakage Analyzer Max 48V Tool JQ
Specifications: Type: Automotive Relay Tester, Circuit Breaker Finder, Wire Tracer, Electrical Probe Short Detector, Parasitic Draw Tester Key Features: High-precision current measurement; Built-in flashlight ; All-in-one functionality Use Scenarios: Passenger car circuit troubleshooting; Commercial truck electrical diagnostic; Nighttime/under-hood maintenance; Automotive repair workshops Product Information Material: ABS/PC Measuring Range: 0.01A-19.99A Current Accuracy: ±2% Load Capacity: 20A/48VDC Size: 110 * 45 * 30 MM (main unit) Line length: 66 CM Packaging: 250 * 152 * 35 MM Package List: 1 * Automotive Current Tester .
Clamp Leakage Current Meter Tester AC Meter Tester 0.00mA to 1200A
Clamp Leakage Current Meter Tester AC Meter Tester 0.00mA to 1200A FeatureETCR6800 High Accuracy Clamp Leakage Current Meter suitable for measuring AC current and leakage current below 600V, range: 0.00mA~1200A, CT size: Φ68mm, the iron core adopts magnetic shielding technology, almost unaffected by the external magnetic field, strong anti-interference ability. Especially suitable for high accuracy small current measurement, adopt non-contact current measurement, safe and simple operation.The instrument is small size, high accuracy, performance stable and function perfect, which is one of the necessary tools for electrician safety inspection and maintenance. The instrument with data hold, data storage and other functions, can store 99 groups of data, the instrument connect computer by RS232 interface, stotage data can be uploaded to the computer, easy to read, analysis, save, print and so on. SpecificationPower Supply:9V(6LR61) CT Size:Φ68mm LCD Size:32mm×15mm Range: AC 0.00mA~1200A Resolution:0.01mA Accuracy:±1.5%rdg±5dgt(23℃±5℃,below 75%rh) Data Storage:99 groups Data Upload Function: Storage data can be uploaded to the computer, save and print Automatic Shutdown:5 Minutes after power on will shutdown automatically without any operation Power Consumption:≤5mA,continuous working 80 hours Working Environment: -10℃~50℃;20%rh~80%rh Store Environment:-10℃~60℃;Below 70%rh Measurement Method: Clamp CT,Non-contact measurement, integration mode Frequency: 50Hz、60Hz Automatic Identification Peak Hold: Peak value capture and hold function, long press HOLD key display peak value Data Hold: Data hold function: “DH” symbol display Overflow Display:Exceed measure range overflow function: “OLA” symbol display Line Voltage: below 600V circuit test Shift:Automatic Measurement Time: 0.5 second/times Voltage Alarm:When battery voltage lower than 7.2V, the low battery voltage symbol will display Insulation Strengh: AC2kV/rms(Between iron core and shell) Suitable Safe Standard: IEC1010-1、IEC1010-2-032、Pollution 2、CAT Ⅲ(600V) Meter Weight:500g Meter Dimension: 224mm(L)×115mm(W)×43mm(H) PAYMENT INFORMATION: 1.We can accept Credit Cards,Paypal,T/T,Escrow and so on.2.The buyer is responsible for any tax and/or duty charged by their country. INTERNATIONAL SHIPPING: The package will be shipped by EUB DHL, FEDEX or EMS. After we shipped the parcel,we’ll fill in the tracking number and inform you by e-mail.Please write the correct address and telephone number when you make orders,so the courier can contact you when they deliver the parcel to you. Thanks! WARRANTY INFORMATION: 1.All the products have been checked and packed in good condition before dispatch.2.All the products with one year warranty.3.If you find any quality problems,please send it back within 3 days,and we’ll send you a new one or refund you the payment after we get the returned one.4.Buyers have to pay for the return cost and we will pay the cost for resend5.All products returned should be in new conditions.
CNBJ-611 Automotive Fuse Current Tester Car Leakage Analyzer Fault Tester6580
Compact and, easy to carry around for on-site testing. Fuse type: standard. [Compact Design]: Beautiful appearance with fashionable color, the body is made of anti-slip ABS/PC material and wrapped with rubber, comfortable to the grip, ensuring a firm grip and operation.
HIOKI AC LEAKAGE CLAMP METER CM4003
Part Number: CM4003. Leakage Current (mA): 6. AC current (A): 200. Width (mm): 64. Depth (mm): 36. Height (mm): 233. connection cable.