Tri-State Building Renovation Inc.

Phone

718-794-0003

Email

tristate2749@gmail.com

Location

NY, NJ and CT area

Ammonia Gas Detector Digital Gas Alarm Infrared Gas Analyzer Range 0-100PPm

Ammonia Gas Detector Digital Gas Alarm Infrared Gas Analyzer Range 0-100PPm

USD 306.00 USD
SKU: mPWOKN8V
Condition: New

Specifications

Return Shipping Will Be Paid ByBuyer
All Returns AcceptedReturns Accepted
Item Must Be Returned Within30 Days
Sensor Gas Sampling:Natural diffusion
Working Humidity<95%;
MPN2023
Power SupplyDC24V±25%
Working Temperature-20℃~70℃
BrandCNYST
Transmit Distance≤1000m
TypeGas Detector
Power Consumption≤3W
Indication Method:4-digit LED light
Pressure Limit:86kPa~106kPa
Country/Region Of ManufactureChina

Ammonia Gas Detector Digital Gas Alarm Infrared Gas Analyzer Range 0-100PPmNote:Shipping without batteries!!!DescriptionGas detection transmitter: QD6330 gas sensing transducer can be used in inflammable and explosive gas leakage places and poisonous and harmful chemical factory, instrument adopted the latest foreign catalytic combustion sensor and its us import electrochemical sensor technology, stable signal, high precision, instrument shell is made of cast aluminum a forming explosion-proof design, connection mode is suitable for all kinds of dangerous areas. Instrument is widely used in pharmaceutical,chemical fertilizer, natural gas pipe network, sewage treatment, municipal, iron smelting steel, chlorine gas plants, acetylene plant, refrigeration plants, chemical plants, gas station, boiler room, hotel kitchen preparation need antivirus for fire and explosion prevention. Gas detectedMeasuring RangeOptional RangeResolution RatioResponse TimeLEL -combustible gas 0-100%LEL0-100%VOL(Infrared or catalytic )1%LEL/1%vol≤10s carbon monoxide0-1000PPm0-500/2000/5000PPm0.1/1PPm≤10sTVOC0-100PPM0-100PPM0.1PPm/1PPM≤15shydrogen0-100%LEL0-1000PPM1%LEL/1PPM≤15snatural gas0-100%LEL0-100%LEL1%LEL≤10sOxygen-O20-30%VOL0-30%、0-100%VOL0.1%vol≤10sozone0-10PPm0-20、100PPm0.01PPm/0.1PPM≤15shydrogen sulfide-H2S0-100PPm0-50、200、1000PPm1/0.1PPm≤10sMethane-CH40-100%LEL0-100%VOL1%LEL/1%vol≤10sfluorine0-10PM0-1、10PPM1/0.1PPm≤15shydrogen chloride0-20PPm0-20/50PPm/100PPM0.01/0.1PPm≤15sNitrogen-N20-30%VOL0-30%VOL、100%VOL0.1%LEL/1PPM≤10shydrogen0-100%LEL0-1000PPm1%LEL/0.1PPm≤15schlorine0-20PPm0-10、100PPm0.1PPm≤15sammonia gas0-100PPm0-50、500、1000PPm1/0.1PPm≤15sThe below gases are available Functions Features· Alarm record query function· Detection accuracy adjustable, adjustable range· Long life, high sensitivity, low drift, stable and reliable work · Sensor fault self test, two levels of alarm, with the relay output function · LCD or LED gas concentration digital display and working status display· With temperature compensation, automatic zero correction function· RS485 digital output, can upload PLC, DCS system· Infrared remote control mode, without cover can be adjusted to the detector, safe and convenient· The design of explosion proof is applied to the 1 and 2 zone of the dangerous conditionTechnical ParametersSensor typeCatalytic or electrochemical gasSensor Gas sampling:Natural diffusionIndication method:4-digit LED lightCondition display3 LED lights indicate fault alarm,L-alarm level alarm and H-alarm level Operation: Infraredremote control ResponseWorking temperature-20℃~70℃Working humidity<95%;Explosion proof wayexplosion proof typeExplosion-proofEx dⅡC T6 GbPower supplyDC24V±25%Switch quantity2(two alarm points often open )Power consumption≤3WCable dimensiontap≥1.5mm2×3BUS≥1.5mm2×4Transmit distance≤1000mWeight≤1500g Pressure Limit:86kPa~106kPaExplosion proof numberCNex19.4492X Measuring mark Henan no. 01000109

Related Items