Country/Region Of ManufactureChina
Linearity:±2%
Resolution:1µmol/m²·s
Unit:µmol/m²·s
Sampling Time:2.5 times/s
Wavelength Range:400nm-700nm
Wavelength Range:400nm-700nm
TypeQuantum Flux Meter
MPN4675678
BrandVTSYIQI

PAR Meter Quantum Flux Meter With Waterproof Sensor Stretch Rod For Underwater Plant Note: Battery not Included During The Shipping !!! I. Introduction This product is an instrument to measure the photosynthetic effective radiation intensity in the natural light or simulated natural light in the wavelength range of 400-700nm. It is mainly applicable to the detection of the irradiation intensity in the effective wavelength range of green plant growth photosynthesis. It has a wide range of uses in agricultural production and scientific research, aquaculture, flower planting, horticulture, etc. It is especially suitable for the detection of simulated natural light sources for household ornamental fish farming and ornamental plant cultivation (such as detecting LED plant growth fill light). II. Features Peak hold function Data retention function Dual-channel detection of photosynthetically effective radiation, can routinely detect in the air and equipped with a waterproof probe for underwater detection. Waterproof probe automatically recognizes and automatically switches to the measurement reading. III. Specifications Resolution:1µmol/m²·s Unit:µmol/m²·s is photosynthesis rate, 1mW/cm2=46 µmol/m²·s Error range:±(10%R+2dgt) R: reading (detecting a composite light source that approximates the sunlight spectrum) The reading error will increase under incandescent lamp or monochromatic yellow light. Display:3-3/4 LCD display, maximum displayed numerical value 3999, over load “OL” Drift: ≦±2% /year Linearity:±2% Measuring range:0-2700µmol/m²·s(400-700nm) Wavelength range:400nm-700nm( fit photosynthetic effective function) Sampling time: 2.5 times/s Operation temperature and humidity: 0°C to 40°C <80%RH Storage temperature and humidity: -10°C to 50°C <70%RH Dimensions and weight: 132(L) 60(W) 38(H)mm, approx. 150g Power: 6F22 alkaline 9V battery (not included) Battery operation life: Approx. 100 hours

Related Items